IMS - Biocleanroom
Malvern Zetasizer Nano ZS

Keywords: Georgia Tech, gatech, organic, cleanroom, analysis, materials, characterization, zetasizer, particle size, zeta potential, malvern, nanoZS, surface zeta potential

Information
Schedule
Training
Equipment Description

The Georgia Tech Zetasizer Nano ZS, located in the Georgia Tech Biocleanroom, is a high performance two angle particle and molecular size analyzer for the enhanced detection of aggregates and measurement of small or dilute samples, and samples at very low or high concentration using dynamic light scattering with ‘NIBS’ optics. The ZSP also incorporates a zeta potential analyzer that uses electrophoretic light scattering for particles, molecules and surfaces, and a molecular weight analyzer using static light scattering.

Using Non-Invasive Backscatter optics (NIBS) it has significantly better performance than systems using 90 degree scattering optics.

In addition, a microrheology option is available for measuring sample viscosity and viscoelastic properties, as well as a Protein Measurement option for protein mobility measurements.

The flow mode option enables the system to be connected to an SEC or an FFF system to use as a detector for the size of proteins or nanoparticles.

A choice of cuvettes are available, from disposable single-use to specific cells for viscous or high concentration samples or measuring the zeta potential of surfaces.

Parameters measured:
Particle and molecule size, translational diffusion, electrophoretic mobility, zeta potential of particles at high and low concentrations, viscosity and viscoelasticity of protein and polymer solutions, concentration, MW, A2, kD.

An optional accessory enables measurement of the zeta potential of solid surfaces.

  • Size measurement from 0.3nm (diameter) to 10 microns using patented NIBS (Non-Invasive Back Scatter) technology.
  • Zeta potential using patented M3-PALS technology.
  • Molecular weight measurement down to 980Da.
  • Microrheology option to measure viscosity and viscoelasticity.
  • Protein size measurement as dilute as 0.1mg/mL (Lysozyme).
  • Sample concentrations from 0.1ppm to 40%w/v.
  • Optional protein calculators, including protein charge, A2, kD, and molecular shape.
  • A ‘Quality Factor’ and ‘Expert Advice System’ gives the confidence of having an expert at your shoulder.
  • 21CFR part 11 software option to enable compliance with ER/ES.
  • Research software option to give access to further features and analysis algorithms for the light scattering specialist.
  • Automation of measurements using an autotitrator option.
  • Optional flow mode capability to enable use as a GPC / SEC size detector.
  • Alternative laser, 50mW at 532nm for samples incompatible with the standard 633nm laser.
  • Optical filter option to improve measurements with fluorescent sample.
  • Temperature range extension option to 120ºC.
Institute Georgia Tech
Department IMS- Micro/Nano Fabrication Facility
Sub Tool Of
Georgia Tech Biocleanroom
System Specifications -Compatible with particles ranging from 0.6nm - 6 microns

-173 degree backscatter beam system

-633nm laser wavelength
Applications Useful for the following:

-Determining particle size/number/volume distributions in suspensions

-Compatible with polypeptides, proteins, micelles, viruses, Colloids, Sols, & nanoparticles

-Measuring Zeta potential as well as surface zeta potential

-Measuring distributions and values of molecular weight
Related Links
Contact Information